SULJE VALIKKO

avaa valikko

Identification of Heterotrophic Bacteria That Colonize Chloraminated Drinking Water Distribution Systems
329,40 €
IWA Publishing
Sivumäärä: 124 sivua
Asu: Pehmeäkantinen kirja
Julkaisuvuosi: 2009, 01.07.2009 (lisätietoa)
Kieli: Englanti
Bacterial regrowth in chloraminated distribution systems encompasses the growth of ammonia-oxidizing bacteria (AOB), nitrite-oxidizing bacteria (NOB), and heterotrophs. While it has been demonstrated that Nitrosomonas oligotropha and Nitrospira spp. are ubiquitous AOB and NOB, respectively, in the drinking water environment, information regarding the identity of heterotrophic bacteria in chloraminated systems is limited. This project was aimed at filling this gap in knowledge by identifying heterotrophs using a 16S rRNA-based molecular biology approach. The objectives of this project were to (1) identify the heterotrophic bacteria that colonize chloraminated distribution systems using bench-scale, pilot-scale, and full-scale environments, (2) determine whether bench-scale and pilot-scale chloraminated systems are adequate models of full-scale chloraminated distribution systems, in regards to heterotrophic bacteria, and (3) explore the development of an automated ribosomal intergenic spacer analysis (ARISA)-based screening test to identify culturable heterotrophic bacteria in drinking water distribution systems.
A molecular biology approach based on the 16S rRNA as a phylogenetic marker was used to identify the heterotrophic bacteria. In addition, ARISA was used for community fingerprinting. Finally, ARISA was explored as a rapid screening and identification test for colonies grown in agar plates. The following environments were studied: Two bench-scale reactors simulating chloraminated and non-chloraminated environments, respectively. Two pilot-scale distribution systems operated at the University of Wisconsin (UW) and two pilot-scale systems operated by the Louisville Water Company. The UW systems evaluated chloramine dose, while the Louisville systems compared the absence of chloramines with chloramines plus chlorite. Finished water and two water tanks in the distribution system at Louisville. For all environments, only bulk water samples were analyzed.

Tuotetta lisätty
ostoskoriin kpl
Siirry koriin
LISÄÄ OSTOSKORIIN
Tuotteella on huono saatavuus ja tuote toimitetaan hankintapalvelumme kautta. Tilaamalla tämän tuotteen hyväksyt palvelun aloittamisen. Seuraa saatavuutta.
Myymäläsaatavuus
Helsinki
Tapiola
Turku
Tampere
Identification of Heterotrophic Bacteria That Colonize Chloraminated Drinking Water Distribution Systemszoom
Näytä kaikki tuotetiedot
ISBN:
9781843392439
Sisäänkirjautuminen
Kirjaudu sisään
Rekisteröityminen
Oma tili
Omat tiedot
Omat tilaukset
Omat laskut
Lisätietoja
Asiakaspalvelu
Tietoa verkkokaupasta
Toimitusehdot
Tietosuojaseloste