SULJE VALIKKO

avaa valikko

Q.H. Wu | Akateeminen Kirjakauppa

Haullasi löytyi yhteensä 7 tuotetta
Haluatko tarkentaa hakukriteerejä?



Protective Relaying of Power Systems Using Mathematical Morphology
Q.H. Wu; Zhen Lu; Tianyao Ji
Springer (2009)
Kovakantinen kirja
147,10
Tuotetta lisätty
ostoskoriin kpl
Siirry koriin
Protective Relaying of Power Systems Using Mathematical Morphology
Q.H. Wu; Zhen Lu; Tianyao Ji
Springer (2010)
Pehmeäkantinen kirja
121,50
Tuotetta lisätty
ostoskoriin kpl
Siirry koriin
Protective Relaying of Power Systems Using Mathematical Morphology
Q. H. Wu; Z. Lu; T. y. Ji
SPRINGER VERLAG GMBH (2009)
Pehmeäkantinen kirja
64,70
Tuotetta lisätty
ostoskoriin kpl
Siirry koriin
IP Network-based Multi-agent Systems for Industrial Automation - Information Management, Condition Monitoring and Control of Pow
David P. Buse; Q.H. Wu
Springer London Ltd (2007)
Kovakantinen kirja
97,90
Tuotetta lisätty
ostoskoriin kpl
Siirry koriin
Condition Monitoring and Assessment of Power Transformers Using Computational Intelligence
W.H. Tang; Q.H. Wu
Springer (2011)
Kovakantinen kirja
129,90
Tuotetta lisätty
ostoskoriin kpl
Siirry koriin
IP Network-based Multi-agent Systems for Industrial Automation : Information Management, Condition Monitoring and Control of Pow
David P. Buse; Q.H. Wu
Springer (2010)
Pehmeäkantinen kirja
97,90
Tuotetta lisätty
ostoskoriin kpl
Siirry koriin
Condition Monitoring and Assessment of Power Transformers Using Computational Intelligence
W.H. Tang; Q.H. Wu
Springer (2013)
Pehmeäkantinen kirja
129,90
Tuotetta lisätty
ostoskoriin kpl
Siirry koriin
Protective Relaying of Power Systems Using Mathematical Morphology
147,10 €
Springer
Sivumäärä: 208 sivua
Asu: Kovakantinen kirja
Painos: 2009
Julkaisuvuosi: 2009, 19.05.2009 (lisätietoa)
Kieli: Englanti
Tuotesarja: Power Systems
The basic principle of protective relaying of power systems has not changed for more than half a century. Almost all power system protective relaying algorithms are dominated by integral transforms such as the Fourier transform and the wavelet transform. The integral transform can only provide an average attribute of the s- nals or their components. The accuracy of the attribute extraction is signi?cantly sacri?ced by the assumption of periodicity of the signals if the integral transform is appliedto transientsignals. Itis also wellknownthatthe signalsare liable to bec- taminatedbynoiseintheformofexponentiallydecayingDCoffsets,highfrequency transients, harmonic distortion, errors caused by non-linearityin the response of the sensors, and unwanted behaviour of power systems. This contamination is often provoked by fault conditions, just at the time when the protection relay is required to respond and trip the circuit breaker to limit damage caused by the fault. On the other hand, as we know, in most protection relays, complex computation has to be undertakenwithin a sampling interval, no matter how small the interval, to calculate the coef?cients relevantto the attributes of the signals byusing the integral transform based on a window of samples, and to calculate the relaying algorithms, which are derivedto representthe relationship betweenthese coef?
cientsandpower system faults. If fast transients and high-order harmonics are to be addressed, - tra computing power and facilities are required. Therefore, it can be seen that the current power system relaying algorithms suffer from many problems including - curacy, fast responses, noise, disturbance rejections and reliability.

Tuotetta lisätty
ostoskoriin kpl
Siirry koriin
LISÄÄ OSTOSKORIIN
Tilaustuote | Arvioimme, että tuote lähetetään meiltä noin 4-5 viikossa | Tilaa jouluksi viimeistään 27.11.2024
Myymäläsaatavuus
Helsinki
Tapiola
Turku
Tampere
Protective Relaying of Power Systems Using Mathematical Morphologyzoom
Näytä kaikki tuotetiedot
ISBN:
9781848824980
Sisäänkirjautuminen
Kirjaudu sisään
Rekisteröityminen
Oma tili
Omat tiedot
Omat tilaukset
Omat laskut
Lisätietoja
Asiakaspalvelu
Tietoa verkkokaupasta
Toimitusehdot
Tietosuojaseloste