SULJE VALIKKO

Englanninkielisten kirjojen poikkeusaikata... LUE LISÄÄ

avaa valikko

Helmut Becker-Ross | Akateeminen Kirjakauppa

HIGH-RESOLUTION CONTINUUM SOURCE AAS - THE BETTER WAY TO DO ATOMIC ABSORPTION SPECTROMETRY

High-Resolution Continuum Source AAS - The Better Way to Do Atomic Absorption Spectrometry
Bernhard Welz; Helmut Becker-Ross; Stefan Florek; Uwe Heitmann
Wiley-VCH Verlag GmbH (2005)
Kovakantinen kirja
184,50
Tuotetta lisätty
ostoskoriin kpl
Siirry koriin
High-Resolution Continuum Source AAS - The Better Way to Do Atomic Absorption Spectrometry
184,50 €
Wiley-VCH Verlag GmbH
Sivumäärä: 296 sivua
Asu: Kovakantinen kirja
Julkaisuvuosi: 2005, 15.02.2005 (lisätietoa)
Kieli: Englanti
High-resolution continuum source atomic absorption spectrometry (HR-CS AAS) is the most revolutionary innovation since the introduction of AAS in 1955. Here, the authors provide the first complete and comprehensive discussion of HR-CS AAS and its application to the analysis of a variety of difficult matrices. Published just in time with the first commercial instrument available for this new technique, the book is a must for all those who want to know more about HR-CS AAS, and in particular for all future users.
The advantages of the new technique over conventional line-source AAS are clearly demonstrated using practical examples and numerous figures, many in full color. HR-CS AAS is overcoming essentially all the remaining limitations of established AAS, particularly the notorious problem of accurate background measurement and correction. Using a continuum radiation source and a CCD array detector makes the spectral environment visible to several tenths of a nanometer on both sides of the analytical line, tremendously facilitating method development and elimination of interferences.
Conceived as a supplement to the standard reference work on AAS by B. Welz and M. Sperling, this book does not repeat such fundamentals as the principles of atomizers or atomization mechanisms. Instead, it is strictly focused on new and additional information required to profit from HR-CS AAS. It presents characteristic concentration for flame atomization and characteristic mass data for electrothermal atomization for all elements, as well as listing numerous secondary lines of lower sensitivity for the determination of higher analyte concentrations. The highly resolved molecular absorption spectra of nitric, sulfuric and phosphoric acids, observed in an air-acetylene flame, which are depicted together with the atomic lines of all elements, make it possible to predict potential spectral interferences.

Tuotetta lisätty
ostoskoriin kpl
Siirry koriin
LISÄÄ OSTOSKORIIN
Tilaustuote | Arvioimme, että tuote lähetetään meiltä noin 3-4 viikossa | Tilaa jouluksi viimeistään 27.11.2024
Myymäläsaatavuus
Helsinki
Tapiola
Turku
Tampere
High-Resolution Continuum Source AAS - The Better Way to Do Atomic Absorption Spectrometryzoom
Näytä kaikki tuotetiedot
ISBN:
9783527307364
Sisäänkirjautuminen
Kirjaudu sisään
Rekisteröityminen
Oma tili
Omat tiedot
Omat tilaukset
Omat laskut
Lisätietoja
Asiakaspalvelu
Tietoa verkkokaupasta
Toimitusehdot
Tietosuojaseloste