SULJE VALIKKO

avaa valikko

Harold Leverenz | Akateeminen Kirjakauppa

Haullasi löytyi yhteensä 2 tuotetta
Haluatko tarkentaa hakukriteerejä?



Evaluation of GHG Emissions from Septic Systems
Harold Leverenz; George Tchobanoglous; Jeannie L. Darby; Giampaolo Zuccheri; Nikolaos Asproulis; Giuseppe Mascolo; Pollice
IWA Publishing (2011)
Saatavuus: Hankintapalvelu
Pehmeäkantinen kirja
238,80
Tuotetta lisätty
ostoskoriin kpl
Siirry koriin
Water Reuse
Metcalf & Eddy, Inc., an AECOM Company, N/A; Takashi Asano; Franklin Burton; Harold Leverenz; Ryujiro Tsuchihashi; Tchobanog
McGraw Hill (2007)
Saatavuus: Painos loppu
Kovakantinen kirja
126,40
Tuotetta lisätty
ostoskoriin kpl
Siirry koriin
IWA Publishing
Sivumäärä: 124 sivua
Asu: Pehmeäkantinen kirja
Julkaisuvuosi: 2011, 15.12.2011 (lisätietoa)
Kieli: Englanti
The emission rates of greenhouse gases (GHGs) from individual onsite septic systems used for the management of domestic wastewater were determined in this study. A static flux chamber method was used to determine the emission rates of methane, carbon dioxide, and nitrous oxide gases from eight septic tanks and two soil dispersal systems. A technique developed for the measurement of gas flow and concentration at clean-out ports was used to determine the mass flow of gases moving through the household drainage and vent system. 


There was general agreement in the methane emission rates for the flux chamber and vent system methods. Several sources of variability in the emission rates were also identified. The septic tank was the primary source of methane, whereas the soil dispersal system was the principal source of carbon dioxide and nitrous oxide emissions. Methane concentrations from the soil dispersal system were found to be near ambient concentrations, similarly negligible amounts of nitrous oxide were found in the septic tank. All emissions originating in the soil dispersal system were discharged through the building vent as a result of natural, wind-induced flow. The gaseous emission rate data were determined to be geometrically distributed. The geometric mean and standard deviation (sg) of the total atmospheric emission rates for methane, carbon dioxide, and nitrous oxide based on samples from the vent system were estimated to be 10.7 (sg = 1.65), 335 (sg = 2.13), and 0.20 (sg = 3.62) g/capita•d, respectively. The corresponding total anthropogenic CO2 equivalence (CO2e) of the GHG emissions to the atmosphere, is about 0.1 tonne CO2e/capita•yr.

Tuotetta lisätty
ostoskoriin kpl
Siirry koriin
LISÄÄ OSTOSKORIIN
Tuotteella on huono saatavuus ja tuote toimitetaan hankintapalvelumme kautta. Tilaamalla tämän tuotteen hyväksyt palvelun aloittamisen. Seuraa saatavuutta.
Myymäläsaatavuus
Helsinki
Tapiola
Turku
Tampere
Evaluation of GHG Emissions from Septic Systemszoom
Näytä kaikki tuotetiedot
ISBN:
9781843396161
Sisäänkirjautuminen
Kirjaudu sisään
Rekisteröityminen
Oma tili
Omat tiedot
Omat tilaukset
Omat laskut
Lisätietoja
Asiakaspalvelu
Tietoa verkkokaupasta
Toimitusehdot
Tietosuojaseloste