SULJE VALIKKO

Englanninkielisten kirjojen poikkeusaikata... LUE LISÄÄ

avaa valikko

Donald Reimert | Akateeminen Kirjakauppa

PROTECTIVE RELAYING FOR POWER GENERATION SYSTEMS

Protective Relaying for Power Generation Systems
Donald Reimert
Taylor & Francis Inc (2005)
Kovakantinen kirja
261,90
Tuotetta lisätty
ostoskoriin kpl
Siirry koriin
Protective Relaying for Power Generation Systems
261,90 €
Taylor & Francis Inc
Sivumäärä: 592 sivua
Asu: Kovakantinen kirja
Painos: 1
Julkaisuvuosi: 2005, 09.12.2005 (lisätietoa)
Kieli: Englanti
Power outages have considerable social and economic impacts, and effective protection schemes are crucial to avoiding them. While most textbooks focus on the transmission and distribution aspects of protective relays, Protective Relaying for Power Generation Systems is the first to focus on protection of motors and generators from a power generation perspective. It also includes workbook constructions that allow students to perform protection-related calculations in Mathcad® and Excel®.

This text provides both a general overview and in-depth discussion of each topic, making it easy to tailor the material to students' needs. It also covers topics not found in other texts on the subject, including detailed time decrement generator fault calculations and minimum excitation limit. The author clearly explains the potential for damage and damaging mechanisms related to each protection function and includes thorough derivations of complex system interactions. Such derivations underlie the various rule-of-thumb setting criteria, provide insight into why the rules-of-thumb work and when they are not appropriate, and are useful for post-incident analysis. The book's flexible approach combines theoretical discussions with example settings that offer quick how-to information.

Protective Relaying for Power Generation Systems integrates fundamental knowledge with practical tools to ensure students have a thorough understanding of protection schemes and issues that arise during or after abnormal operation.

Tuotetta lisätty
ostoskoriin kpl
Siirry koriin
LISÄÄ OSTOSKORIIN
Tilaustuote | Arvioimme, että tuote lähetetään meiltä noin 1-3 viikossa. | Tilaa jouluksi viimeistään 27.11.2024. Tuote ei välttämättä ehdi jouluksi.
Myymäläsaatavuus
Helsinki
Tapiola
Turku
Tampere
Protective Relaying for Power Generation Systemszoom
Näytä kaikki tuotetiedot
Sisäänkirjautuminen
Kirjaudu sisään
Rekisteröityminen
Oma tili
Omat tiedot
Omat tilaukset
Omat laskut
Lisätietoja
Asiakaspalvelu
Tietoa verkkokaupasta
Toimitusehdot
Tietosuojaseloste